4. ELECTRICAL CONNECTIONS
The electrical connection between the emitting and receiving units is made through a male M12
connector located in the lower part of the light grid.
2
8
1
5
3
4
7
6
+ VDC
GND
TEACH-IN /
(OUTPUT HOLD) / (SERIAL OUTPUT ENABLE)
SYNC
RX/TX -
SWITCHING OUTPUT
ANALOGUE OUTPUT
RX/TX +
RECEIVER (RX):
1 = white = RX/TX -
2 = brown = +VDC
3 = green = ANALOGUE OUT
4 = yellow = SWITCHING OUTPUT
5 = grey = TEACH-IN / (OUT HOLD) / (SERIAL OUT ENABLE)
6 = pink = RX/TX +
7 = blue = GND
8 = red = SYNC
3
4
2
1
NOT USED
GND
+VDC
SYNC
EMITTER (TX):
1 = brown = +VDC
2 = white = NOT USED
3 = blue = GND
4 = black = SYNC