17: USER COMMUNICATION INSTRUCTIONS
17-14 « FC4A MICROSMART USERS MANUAL »
6. Once again in the Data Type Selection dialog box, click Constant (Hexadecimal) and click OK. Next, in the Constant
(Hexadecimal) dialog box, type 03 to program the end delimiter ETX (03h). When finished, click OK.
7. In the Transmit instruction dialog box, type M10 in the destination D1 box and type D100 in the destination D2 box.
When finished, click OK.
Programming of the TXD1 instruction is complete and the transmit data is specified as follows:
STX
(02h)
D10
“1”
(31h)
“2”
(32h)
“3”
(33h)
“4”
(34h)
“5”
(35h)
“8”
(38h)
BCC
(41h)
ETX
(03h)
BCC
“6”
(36h)
“7”
(37h)
BCC calculation range
Constant D11 Constant
(H)
BCC
(36h)
(L)
(hex) (hex)